CNET cn5614xr Especificações Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 86
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
RFI Suppressor Assemblies
1-14 Section 1: Installing the Cabinet DS2000 Hardware Manual
RFI Suppressor Assemblies
Installing RFI Suppressor Assemblies
You must install RFI Suppressor Assemblies as follows (see Figure 1-10
Installing RFI Suppressor Assemblies
below). The suppressors must be mounted inside the cabinet and as close to the appropriate PCB as possible.
For Ground Wires
You must install a separate RFI assembly for the ground wire(s) in all systems.
– If your system has 2 ground wires, install them both in the same assembly.
For CPU Connections
You must install a separate RFI assembly for the CPU mod jack and RS-232 cables in all systems.
– Install both cables in the same assembly.
Figure 1-10: Installing RFI Suppressor Assemblies
For Ground Wires
Required for all installations.
For CPU Connections
Required on CPU mod jack
and RS-232 cables for all
installations.
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 85 86

Comentários a estes Manuais

Sem comentários